Hunter Valley water balance 2010/2011

Water balance component Sources of water Distribution of water % of volume measured
  Volume (ML) % of total Volume (ML) % of total  

Storage Volume

         
Combined volume in storage at start of year     700,093     
Volume in storage at end of period     967,482     
Change in storage 267,390  20%  100% 
Barnard Reserve (4) 11,524  1%  11,524  1%  100% 
Spills     -   100%
Storage net evaporation     21,699 2% 100%

Inflows

         
Storage inflows (1) 341,404  25%    0%  100% 
Downstream tributaries (2) 1,013,396  74%    0%  60% 
Subtotal 1,354,799  99%    0%   

Net water diverted under riparian rights

         
Domestic and stock rights (3)     5,400  0%  0% 
Native title rights       0%   
Subtotal     5,400  0%   

Net Water diverted under access licences

         
Domestic and stock     526  0%  100% 
High security     6,700  0%  100% 
General security     35,693  3%  100%
Local water utility     6,149  0%  100% 
Major utility     23,202  2%  100% 
Supplementary water     43,239  3%  100% 
Subtotal     115,509  8%   

Environmental water

         
Environmental flows (Plan)     32,910  2%  100% 
End of water source flows (5)     911,892  67%  90% 
Subtotal     944,802  69%   

Other outflows

         
Unaccounted difference (6)     0%   
Total 1,366,323  100%  1,366,323  100%   

 Notes

  1. Calculated from Glenbawn and Glennies Creek Dams evaporation and releases, less storage drawdown and Barnard Reserve inflows.
  2. Downstream tributaries - assessed by mass balance at Greta -
  3. Basic rights are not metered. Values presented are those in the Water Sharing Plan.
  4. Barnard Reserve accumulates from an inter valley physical transfer. Volume for 2010-11. Total Barnard 52,389
  5. Gauged at Greta (not the end) - flows greater than environmental target are provided
  6. The actual combined regulated releases from Glenbawn and Glennies Creek Dams

Note: Controlled release for salinity dilution in April